Work very well for my dryer vent and is built to be separated and installed afterwards.
4 pvc pipe for dryer vent.
The pvc runs from the laundry room to an outside wall of the slab and are most likely 8 12 feet long.
Transfer that measurement inside if necessary to mark the new dryer vent center.
Wide duct tape or similar long lasting adhesive tape.
All pvc pipe and fittings have a max operating temp of 140 degrees fahrenheit.
Metal air duct tape.
Builders in this area are using 4 pvc pipe for a dryer vent before they pour the slab for the home.
4 metal pipe will fit in a 3 5 wall.
Do not use duct tape it does not last.
This encases the pvc within the concrete floor.
Securely tape pipe joints with ul listed aluminum foil tape no screws rivets.
Not only is less expensive it is also easier to install and vent warping and dryer overheating is no longer an issue.
Use a 4 1 4 inch hole saw to cut the vent opening.
Apply a sealant to cover this seam.
The dryer works much better now and dries the clothes in much less time.
This pipe has seams where there is potential for air leaks.
For one pvc has a rather low maximum operating temperature.
I replaced it with 4 pvc drainage pipe.
All that hot air and moisture running through the pipe for years is bound to do some damage.
At one inspection from this past spring i even saw a black corrugated plastic drain pipe normally used for draining exterior water from downspouts being used as the home s dryer vent.
The old vent was the plastic slinky with the wire coil.
Dryer vent with 4 pvc pipe.
Imperial indoor hook up dryer vent kit.
This encases the pvc within the concrete floor.
It was a mess sagged and was full of lint.
So in essence use of a pvc pipe as a dryer vent is a fire hazard.
When you assemble the pipe make sure the ends are not opposed to the air flow seal the joints with a 4 quot.
For pricing and availability.
Cut the top and bottom plates about 4 5 or so and stick the dryer vent piping in the wall.
I m pretty sure i recall seeing something in the irc that prohibits pvc venting for dryers.
Something that i ve been running across more often lately in homes built within the past 15 years is some builders installing 4 inch pvc drain pipe as the clothes dryer duct.
For pricing and availability.
Now think about how hot your dryer gets.
I replaced a dryer vent that ran thru my crawl space for a distance of about 15 feet.
Since pvc is not really safe for dryer vents it is recommended to use the flexible aluminum pipes for your dryer vents instead.
Snap to vent master dryer vent connector kit indoor hook up dryer vent kit.